8190 4" SQ BOX 1/2KO'S
Used where multiple conductor runs are split into two or more directions to bring power to a number of electrical devices. Drawn construction and raised grounding provision for exposed work or surface mount applications. Combination cover screw heads provide for faster mudring/cover installation. Twelve 1/2" conduit knockouts (sides). Four 1/2" conduit knockouts (bottom). No bracket. 4" square x 1-1/2" deep - 21.0 cubic inches. UL Listed, acceptable for use in 2-hour fire rated walls. UPC bar code.
- Drawn Construction
- For Conduit
- Drawn construction and raised grounding provision makes this box ideal for surface mount applications
- Combination cover screw heads provide for faster mud ring/cover installation
- Drawn boxes are ideal for exposed work or surface mount applications
- Square boxes are used where multiple conductor runs are split into two or more directions to bring power to a number of electrical devices
- Fire resistance: acceptable for use in 2 hr rated walls
- Side knockout: (12) 1/2 in, Bottom knockout: (4) 1/2 in
View Details
Call for Price
8192 4"SQ BX 1.5"DEEP
Conduit wiring system. Installed in ceilings or walls for lighting fixtures, switches or receptacles. Used where multiple conductor runs are split into two or more directions to bring power to a number of electrical devices. Drawn construction and raised grounding provision for surface mount applications in ceilings or walls for lighting fixtures or receptacles. Eight 1/2"and four 3/4" conduit knockouts (sides). Two 1/2" and two 3/4" conduit knockouts (bottom). 4" square x 1-1/2" deep - 21.0 cubic inches. Acceptable for use in 2-hour rated fire walls. UL Listed. UPC bar code.
- Drawn Construction
View Details
Call for Price
8203 4" SQR EXT RINGS
For adding additional cubic capacity or as an outlet box for surface conduit. Eight 1/2" and four 3/4" conduit knockouts (sides). 4" square x 1-1/2" deep. 22.5 cubic inches. UL Listed.
- Steel
- Drawn Construction
View Details
Call for Price
8257 5" SQUARE BOX
Conduit wiring system. Two 1/2" and twelve TKO conduit knockouts (sides). One 1/2", three TKO conduit knockouts (bottom). No bracket, installed in ceilings or walls for lighting fixtures or receptacles. 4-11/16" square x 2-1/8" deep - 42.0 cubic inches. Combination cover screw heads provide for faster mudring/cover installation. UPC bar code. UL Listed.
- Square - Welded
- Conduit
View Details
Call for Price
8292 3.5" CEILING BOX
Non-metallic sheathed cable wiring system. Clamps in bottom. Four cable knockouts, one 1/2" conduit. 3-1/2" diameter x 1/2" depth. UL Listed.
- Steel - Round
- Ceiling Pan
- Cu In Cap : 3.9
- Combination screw heads provide for faster cover or light fixture installation
- Fire resistance: acceptable for use in 2 hr rated walls and ceilings
- Not designed for ceiling fan support
View Details
Call for Price
8293 4" RND CEILING BX
Five 1/2" bottom conduit knockouts, 6 cubic inch capacity. Acceptable for use in 2-hour rated walls and ceilings. 4" diameter x 1/2" depth. UL Listed.
- Steel - Round
- Drawn Construction
- Cu In Cap : 6
View Details
Call for Price
8355 SWITCH BOX ROMEX
Four cable knockouts (ends). One 1/2" conduit knockout (bottom). With clamps for non-metallic sheathed cable. "S" backset. Mounting guides set 3/8", with bumps. Angle nail type. 3" x 2" x 2-27/32" deep, 15.8 cubic inch capacity. Prepositioned mounting nails included. Acceptable for use in 2-hour rated walls. UL Listed.
- Non-gangable design for single device mounting
- 2-1/8 in box width accommodates GFCI receptacles
- Gauging notches at 3/8 in, 1/2 in and 5/8 in make it easy to position box on stud at correct depth for finished wall
- Prepositioned mounting nails included
- Fire resistance: acceptable for use in 2 hr rated walls
- Bottom knockout: (1) 1/2 in, End knockout: (4) Priouts
View Details
Call for Price
2-1/4" SWITCH BOX WITH EARS
Beveled corner box, designed to prevent the clamp screws from protruding into back wall. Non-metallic sheathed cable clamps. Acceptable for use in 2-hour rated walls. Four cable knockouts (end). One 1/2" conduit knockout (bottom). No bracket, clamp screws through beveled corners. With ears. 3" x 2" x 2-1/4" deep. 10.5 cubic inches. UL Listed.
- Gangable - Old Work
- With Ears - 3 Inch X 2 Inch
View Details
Call for Price
8500 2.5" SW BOX 1/2KO
Conduit wiring system. Four 1/2" conduit knockouts (sides). Two 1/2" conduit knockouts (end). Two 1/2" conduit knockouts (bottom). Less clamps. 3" x 2" x 2-1/2" deep. 12.5 cubic inches. Acceptable for use in 2-hour rated fire walls. UL Listed.
- Gangable
- Old Work - With Ears
View Details
Call for Price
2-1/2" DEEP SWITCH BOX NO EARS
Four cable knockouts (end). Two 1/2" conduit knockouts (end). One 1/2" conduit knockout (bottom). With non-metallic sheathed cable clamps. Leveling bumps. Less ears. 3" x 2" x 2-1/2" deep. 12.5 cubic inches. Acceptable for use in 2-hour rated fire walls. UL Listed.
- Gangable
- Less Ears - 3 Inch X 2 Inch
- Gangable switch box offers the option of constructing a box to hold two or more devices
- Acceptable for use in 2 hr fire rated wall
- Fire resistance: acceptable for use in 2 hr rated walls
- Bottom knockout: (1) 1/2 in, end knockout: (2) 1/2 in and (4) priouts
View Details
Call for Price
8531 2.5" SW BX W/BRKT
Four cable knockouts (end). Two 1/2" conduit knockouts (end). One 1/2" conduit knockout (bottom). With non-metallic sheathed cable clamps. "TS" brackets for wood or metal studs. Gauging tabs and recessed nailing spur. Side mount. 3" x 2" x 2-1/2" deep. 12.5 cubic inches. UL Listed.
- Gangable
- Less Ears - 3 Inch X 2 Inch
View Details
Call for Price
8601 SW BOX 3.5" DEEP
Four 1/2" conduit knockouts (sides). Four cable knockouts (end). Two 1/2" conduit knockouts (end). One 1/2" conduit knockout (bottom). With non-metallic cable clamps in each end. 3" x 2" x 3-1/2" deep. 18.0 cubic inches. Adjustable plaster ears allow box to be used in old work applications. Acceptable for use in 2-hour rated walls. UL Listed.
- Gangable - Old Work
- With Ears - 3 Inch X 2 Inch
- Gangable switch box offers the option of constructing a box to hold two or more devices
- Adjustable plaster ears allow box to be used in "old work" applications
- Fire resistance: acceptable for use in 2 hrs rated walls
- Side knockout: (4) 1/2 in, Bottom knockout: (1) 1/2 in, End knockout: (2) 1/2 in (4) Priouts
View Details
Call for Price
8660 1-7/8DP HANDY BOX
Used for convenience outlets, switch boxes or small junction boxes. Drawn construction and raised grounding provision. Acceptable for use in 2-hour rated walls. Six 1/2" knockouts (sides). Two 1/2" knockouts (ends). Two 1/2" knockouts (bottom). 4" x 2" x 1-7/8" deep. 13.0 cubic inch capacity. UL Listed.
- Handy Box
- Old Work
View Details
Call for Price
1-7/8" UTILITY BOX 3/4" KO
Drawn construction and raised grounding provision for surface mount applications. Four 3/4" knockouts (sides). Two 3/4" knockouts (ends). One 3/4" knockout (bottom). 4" x 2" x 1-7/8" deep. 13.0 cubic inch capacity. UL Listed.
- Handy Box
- Drawn Construction
View Details
Call for Price